PTC has a unique heat property that allows the PTC heat output to be regulated by the airflow applied. The higher the airflow, the higher the heat output and power (wattage). Therefore, depending on the end design, if the ambient temperature is high, the PTC output power will decrease; if the airflow is high with low ambient temperature, then the PTC output power will increase.
1
2
Model Number |
Item Name |
Type |
Rated Voltage |
Maximum Inrush Current |
Thickness |
Add To Cart/Request Quote |
---|---|---|---|---|---|---|
OH(W)-2060M-202S(D) | N/A6 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A6 A | N/A26 mm | Request Quote |
OH(W)-2070M-202S(D) | N/A7 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A7 A | N/A26 mm | Request Quote |
OH(W)-2080M-202S(D) | N/A7 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A7 A | N/A26 mm | Request Quote |
OH(W)-2100M-202S(D) | N/A8 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A8 A | N/A26 mm | Request Quote |
OH(W)-2XXXM-225S(D) | N/A8 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A8 A | N/A26 mm | Request Quote |
OH(W)-2XXXM-269S(D) | N/A10 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A10 A | N/A26 mm | Request Quote |
OH(W)-2XXXM-314S(D) | N/A11 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A11 A | N/A26 mm | Request Quote |
OH(W)-2XXXM-358S(D) | N/A13 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A13 A | N/A26 mm | Request Quote |
OH(W)-2XXXM-403S(D) | N/A14 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A14 A | N/A26 mm | Request Quote |
OH(W)-2XXXM-447S(D) | N/A15 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A15 A | N/A26 mm | Request Quote |
OH(W)-2XXXM-492S(D) | N/A15 Ampere (A) Maximum Inrush Current and 220 Volt (V) Rated Voltage OH-Type Positive Temperature Coefficient (PTC) Air Heater | N/AWired | N/A220 V | N/A15 A | N/A26 mm | Request Quote |
1
2